Cpppo (pronounced ‘c’3*’p’‘o’ in Python) is used to implement binary
communications protocol parsers. The protocol’s communication elements are
described in terms of state machines which change state in response to input
events, collecting the data and producing output data artifacts.
Cpppo depends on several Python packages:
Package | For? | Description |
---|---|---|
greenery>=2.0,<3.0 | all | Regular Expression parsing and state machinery library |
ipaddress | all | IP address manipulation |
argparse | all (<2.7) | Command-line argument parsing |
configparser | all (<3.0) | Parsing for CIP Object configuration files |
pytz>2014.7 | history | The Python time-zone library |
tzlocal>=1.1.1 | history | Access to system’s local timezone (on Mac, Windows) |
pymodbus>=1.2.0 | remote | Modbus/TCP support for polling Schneider compatible PLCs |
pytest | all tests | A Python unit-test framework |
web.py>=0.37 | web API (<3.0) | The web.py HTTP web application framework (optional) |
minimalmodbus | serial tests | A Modbus implementation, used for testing Modbus serial |
To install ‘cpppo’ and its required dependencies using pip (recommended):
$ pip install cpppo
Clone the repo by going to your preferred source directory and using:
$ git clone git@github.com:pjkundert/cpppo.git
You can then install from the provided setuptools-based setup.py installer:
$ cd cpppo $ python setup.py install
If you do not install using pip install cpppo
or python setup.py install
(recommended), you will need to install these dependencies manually. To
install all required and optional Python modules, use:
pip install -r requirements.txt pip install -r requirements-optional.txt
For Python2, you will also need to pip install configparser
manually.
Cpppo is implemented and fully tested on both Python 2 (2.6 and 2.7), and Python 3 (3.3 to 3.5). The EtherNet/IP CIP protocol implementation is fully tested and widely used in both Python 2 and 3.
Some of cpppo’s modules are not (yet) fully supported in both versions:
- The pymodbus module does not support Python 3, so Modbus/TCP support for polling remote PLCs is only available for Python 2.
- Greenery supports both Python 2 and 3, but doesn’t provide meaningful Unicode (UTF-8) support in Python 2, so regular expression based DFAs dealing in UTF-8 are only supported for Python 3.
Linux (native or Docker containerized), Mac and Windows OSs are supported. However, Linux or Mac are recommended for stability, performance and ease of use. If you need to use Windows, it is recommended that you install a usable Terminal application such as ConEmu.
The protocols implemented are described here.
A subset of the EtherNet/IP client and server protocol is implemented, and a simulation of a subset of the Tag communications capability of a Allen-Bradley ControlLogix 5561 Controller is provided. It is capable of simulating ControlLogix Tag access, via the Read/Write Tag [Fragmented] services.
Only EtherNet/IP “Unconnected” type connections are supported. These are (somewhat anomalously) a persistent TCP/IP connection from a client to a single EtherNet/IP device (such as a *Logix Controller), which allow the client to issue a sequence of CIP service requests (commands) to be sent to arbitrary CIP objects resident on the target device. Cpppo does not implement “Connected” requests (eg. those typically used between *Logix PLCs, in an industrial LAN environment).
A Tag is simply a shortcut to a specific EtherNet/IP CIP Object Instance and Attribute. Instead of the Client needing to know the specific Instance and Attribute numbers, the more easily remembered and meaningful Tag may be supplied in the request path.
To run a simulation of a subset of a ControlLogix(tm) Controller
communications, with the array Tags ‘SCADA’ and ‘TEXT’ and scalar Tag ‘FLOAT’
for you to read/write, run python -m cpppo.server.enip
or enip_server
:
enip_server --print SCADA=INT[1000] TEXT=SSTRING[100] FLOAT=REAL
Each Tag references a specific CIP Class/Instance/Attribute, which can be specified, if you desire (eg. to use numeric CIP addressing, typically required for Get/Set Attribute Single requests):
enip_server --print SCADA@22/1/1=INT[1000] TEXT@22/1/2=SSTRING[100] FLOAT@22/1/3=REAL
(See cpppo/server/enip/poll_test.py
’s main
method (at the end of the
file) for an example of how to implement a completely custom set of CIP
Objects and Attributes, to simulate some aspects of some specific device (in
this case, an Allen-Bradley PowerFlex 750).
The following options are available when you execute the cpppo.server.enip module:
Specify a different local interface and/or port to bind to (default is
:44818
, indicating all interfaces and port 44818):
-a|--address [<interface>][:<port>]
Change the verbosity (supply more to increase further):
-v[vv...]|--verbose
Specify a constant or variable delay to apply to every response, in fractional seconds:
-d|--delay #.#[-#.#]
Specify an HTTP web server interface and/or port, if a web API is desired (just ‘:’ will enable the web API on defaults :80, or whatever interface was specified for –address):
-w|--web [<interface>]:[<port>]
To send log output to a file (limited to 10MB, rotates through 5 copies):
-l|--log <file>
To print a summary of PLC I/O to stdout:
-p|--print --no-print (the default)
To specify and check for a specific route_path
in incoming Unconnected Send requests, provide
one in “<port>/<link>” or JSON format; the default is to ignore the specified route_path
(accepting any route_path
). If specified, it must be a list containing one dict, specifying a
port
and link
value. The port
is either an 8- or 16-bit number (eg. port 1 typically
indicates the local backplane). The link
is typically in the range 0-15 (eg. a “slot”
number), or is an IP address (eg. “1.2.3.4”). To specify that no route_path
is accepted
(ie. only an empty route_path
is allowed, ie. a Simple request), use 0 or false:
--route-path '[{"port": 1, "link": 0]' # backplane, slot 0 --route-path 1/0 # '' --route-path '[{"port": 2, "link": "192.168.1.2"}]' # { port 2, link 192.168.1.2 } --route-path 2/192.168.1.2 # '' --route-path 1/0/2/192.168.1.2 # { backplane, slot 0 }, { port 2, link 192.168.1.2 } --route-path false # No route_path accepted
Note that incoming “Simple” requests to a full-featured “Routing” simulator configured with a route path will be accepted; the specified target CIP Object(s) must exist in the target simulator.
Alternatively, to easily specify acceptance of no routing Unconnected Send encapsulation (eg. to simulate simple non-routing CIP devices such as Rockwell MicroLogix or A-B PowerFlex):
-S|--simple
You may specify as many tags as you like on the command line; at least one is required:
<tag>=<type>[<length>] # eg. SCADA=INT[1000]
You may specifiy a CIP Class, Instance and Attribute number for the Tag to be associated with:
Motor_Velocity@0x93/3/10=REAL
The available types are SINT (8-bit), INT (16-bit), DINT (32-bit) integer, and REAL (32-bit float). BOOL (8-bit, bit #0), SSTRING and STRING are also supported.
To replace the default values contained by default in the standard CIP
Objects (eg. the CIP Identity, TCP/IP Objects), place a cpppo.cfg
file in
/etc
or (on Windows) %APPDATA%
, or a .cpppo.cfg
in your home
directory, or a cpppo.cfg
file in the current working directory where your
application is run.
For example, to change the simulated EtherNet/IP CIP Identity Object
‘Product Name’ (the SSTRING at Class 0x01, Instance 1, Attribute 7), and the
CIP TCP/IP Object Interface Configuration and Host Name, create a
cpppo.cfg
file containing:
[Identity] # Generally, strings are not quoted Product Name = 1756-L61/B LOGIX5561 [TCPIP] # However, some complex structures require JSON configuration: Interface Configuration = { "ip_address": "192.168.0.201", "network_mask": "255.255.255.0", "dns_primary": "8.8.8.8", "dns_secondary": "8.8.4.4", "domain_name": "example.com" } Host Name = controller
See https://github.com/pjkundert/cpppo/blob/master/cpppo.cfg for details on the file format (https://docs.python.org/3/library/configparser.html).
Place this file in one of the above-mentioned locations, and run:
$ python -m cpppo.server.enip -v 01-20 07:01:29.125 ... NORMAL main Loaded config files: ['cpppo.cfg'] ...
Use the new EtherNet/IP CIP cpppo.server.enip.poll
API to poll the
Identity and TCPIP Objects and see the results:
$ python3 -m cpppo.server.enip.poll -v TCPIP Identity 01-20 07:04:46.253 ... NORMAL run Polling begins \ via: 1756-L61/C LOGIX5561 via localhost:44818[850764823] TCPIP: [2, 48, 0, [{'class': 246}, {'instance': 1}], '192.168.0.201', \ '255.255.255.0', '0.0.0.0', '8.8.8.8', '8.8.4.4', 'example.com', 'controller'] Identity: [1, 15, 54, 2836, 12640, 7079450, '1756-L61/C LOGIX5561', 255]
A very basic facility for routing incoming CIP requests with complex route_path
values is
available in the Cpppo EtherNet/IP CIP Communications Simulator. By default, the Simulator
responds to incoming requests with any route_path (basically, it ignores the value).
If you specify --route-path=1/0
on the command-line, it will only respond to requests with
exactly the route_path
equal to ‘{“port”: 1, “link”: 0}’ (backplane, slot 0). Every other
CIP reqeuest with some other route_path
value will be responded to with an error status.
If you wish to configure the allowable route_path
in the cpppo.cfg
file, use “Route Path =
…”. Furthermore, if you want to route any other valid CIP request by the first element in
its route_path
, specify a JSON mapping in the configuration file’s “Route = { …”,
specifying each route_path
by <port>/<link> (link ranges are handled), and the <IP>:<port> it
should be routed to:
[UCMM] Route Path = 1/0 Route = { "1/1-15": "localhost:44819" }
This example (see cpppo/cpppo-router.cfg
and cpppo/cpppo.cfg
for more details) accepts and
handles CIP requests to route_path
port 1, link 0 (backplane slot 0), and routes requests to
all other backplane slots to the EtherNet/IP CIP simulator on localhost port 44819. Any valid
route_path
is allowed; for example, “2/1.2.3.4” would route requests with a route_path
segment specifying port 2, link “1.2.3.4”.
When the request is forwarded, the first route_path
segment is removed, and the remaining
segments (if any) are forwarded. If no more route_path
segments are left, then the request
is forwarded as a “Simple” CIP request (with no route_path
or send_path
configured, as for
a simple non-routing CIP device such as a MicroLogix or A-B Powerflex, etc.)
If you require access to the read and write I/O events streaming from client(s) to and from the EtherNet/IP CIP Attributes hosted in your simulated controller, you can easily make a custom cpppo.server.enip.device Attribute implementation which will receive all PLC Read/Write Tag [Fragmented] request data.
We provide two examples; one which records a history of all read/write events to each Tag, and one which connects each Tag to the current temperature of the city with the same name as the Tag.
For example purposes, we have implemented the cpppo.server.enip.historize
module which simulates an EtherNet/IP CIP device, intercepts all I/O (and
exceptions) and writes it to the file specified in the first command-line
argument to the module. It uses cpppo.history.timestamp
, and requires
that the Python pytz
module be installed (via pip install pytz
), which
also requires that a system timezone be set.
This example captures the first command line argument as a file name; all subsequent arguments are the same as described for the EtherNet/IP Controller Communications Simulator, above:
$ python -m cpppo.server.enip.historize some_file.hst Tag_Name=INT[1000] & $ tail -f some_file.txt # 2014-07-15 22:03:35.945: Started recording Tag: Tag_Name 2014-07-15 22:03:44.186 ["Tag_Name", [0, 3]] {"write": [0, 1, 2, 3]} ...
(in another terminal)
$ python -m cpppo.server.enip.client Tag_Name[0-3]=[0,1,2,3]
You can examine the code in cpppo/server/enip/historize.py
to see how to
easily implement your own customization of the EtherNet/IP CIP Controller
simulator.
If you invoke the ‘main’ method provided by cpppo.server.enip.main directly, all command-line args will be parsed, and the EtherNet/IP service will not return control until termination. Alternatively, you may start the service in a separate threading.Thread and provide it with a list of configuration options. Note that each individual EtherNet/IP Client session is serviced by a separate Thread, and thus all method invocations arriving at your customized Attribute object need to process data in a Thread-safe fashion.
In this example, we intercept read requests to the Tag, and look up the
current temperature of the city named with the Tag’s name. This example is
simple enough to include here (see cpppo/server/enip/weather.py
):
import sys, logging, json try: # Python2 from urllib2 import urlopen from urllib import urlencode except ImportError: # Python3 from urllib.request import urlopen from urllib.parse import urlencode from cpppo.server.enip import device, REAL from cpppo.server.enip.main import main as enip_main class Attribute_weather( device.Attribute ): OPT = { "appid": "078b5bd46e99c890482fc1252e9208d5", "units": "metric", "mode": "json", } URI = "http://api.openweathermap.org/data/2.5/weather" def url( self, **kwds ): """Produce a url by joining the class' URI and OPTs with any keyword parameters""" return self.URI + "?" + urlencode( dict( self.OPT, **kwds )) def __getitem__( self, key ): """Obtain the temperature of the city's matching our Attribute's name, convert it to an appropriate type; return a value appropriate to the request.""" try: # eg. "http://api.openweathermap.org/...?...&q=City Name" data = urlopen( self.url( q=self.name )).read() if type( data ) is not str: # Python3 urlopen.read returns bytes data = data.decode( 'utf-8' ) weather = json.loads( data ) assert weather.get( 'cod' ) == 200 and 'main' in weather, \ weather.get( 'message', "Unknown error obtaining weather data" ) cast = float if isinstance( self.parser, REAL ) else int temperature = cast( weather['main']['temp'] ) except Exception as exc: logging.warning( "Couldn't get temperature for %s via %r: %s", self.name, self.url( q=self.name ), exc ) raise return [ temperature ] if self._validate_key( key ) is slice else temperature def __setitem__( self, key, value ): raise Exception( "Changing the weather isn't that easy..." ) sys.exit( enip_main( attribute_class=Attribute_weather ))
By providing a specialized implementation of device.Attribute’s __getitem__
(which is invoked each time an Attribute is accessed), we arrange to query
the city’s weather at the given URL, and return the current temperature.
The data must be converted to a Python type compatible with the eventual
CIP type (ie. a float, if the CIP type is REAL). Finally, it must be
returned as a sequence if the __getitem__
was asked for a Python slice
;
otherwise, a single indexed element is returned.
Of course, __setitem__
(which would be invoked whenever someone wishes to
change the city’s temperature) would have a much more complex
implementation, the details of which are left as an exercise to the
reader…
Cpppo provides an advanced EtherNet/IP CIP Client enip_client
, for
processing “Unconnected” (or “Explicit”) requests via TPC/IP or UDP/IP
sessions to CIP devices – either Controllers (eg. Rockwell ControlLogix,
CompactLogix) which can “route” CIP requests, or w/ the -S
option for
access to simple CIP devices (eg. Rockwell MicroLogix, A-B PowerFlex, …)
which do not understand the “routing” CIP Unconnected Send encapsulation
required by the more advanced “routing” Controllers.
Cpppo does not presently implement the CIP “Forward Open” request, nor the resulting “Connected” or “Implicit” I/O requests, typically used in direct PLC-to-PLC communications. Only the TCP/IP “Unconnected”/”Explicit” requests that pass over the initially created and CIP Registered session are implemented.
The python -m cpppo.server.enip.client
module entry-point or API (or the
enip_client
command ) can Register and issue a stream of “Unconnected”
requests to the Controller, such as Get/Set Attribute or (by default) *Logix
Read/Write Tag (optionally Fragmented) requests. The
cpppo.server.enip.get_attribute
module entry-point or API and the
enip_get_attribute
command defaults to use Get/Set Attribute operations.
It is critical to use the correct API with the correct address type and
options, to achieve communications with your device. Some devices can use
“Unconnected” requests, while others cannot. The MicroLogix is such an
example; you may use “Unconnected” requests to access basic CIP Objects
(such as Identity), but not much else. Most other devices can support
“Unconnected” access to their data. Some devices can only perform basic CIP
services such as “Get/Set Attribute Single/All” using numeric CIP Class,
Instance and Attribute addressing, while others support the *Logix
“Read/Write Tag [Fragmented]” requests using Tag names. You need to know
(or experiment) to discover their capability. Still others such as the
CompactLogix and ControlLogix Controllers can support “routing” requests;
many others require the -S
option to disable this functionality, or they
will respond with an error status.
To issue Read/Write Tag [Fragmented] requests, by default to a “routing”
device (eg. ControlLogix, CompactLogix), here to a CIP INT
array Tag called
SCADA
, and a CIP SSTRING
(Short String) array Tag called TEXT
:
$ python -m cpppo.server.enip.client -v --print \ SCADA[1]=99 SCADA[0-10] 'TEXT[1]=(SSTRING)"Hello, world!"' TEXT[0-3]
To use only Get Attribute Single/All requests (suitable for simpler devices,
usually also used with the -S
option, for no routing path), use this API
instead (use the --help
option to see their options, which are quite
similar to cpppo.server.enip.client
and enip_client
):
$ python -m cpppo.server.enip.get_attribute -S ...
All data is read/written as arrays of SINT
; however, if you specify a data
type for writing data, we will convert it to an array of SINT
for you. For example,
if you know that you are writing to a REAL
Attribute:
$ python -m cpppo.server.enip -v 'Motor_Velocity@0x93/3/10=REAL' # In another terminal... $ python -m cpppo.server.enip.get_attribute '@0x93/3/10=(REAL)1.0' '@0x93/3/10' Sat Feb 20 08:24:13 2016: 0: Single S_A_S @0x0093/3/10 == True Sat Feb 20 08:24:13 2016: 1: Single G_A_S @0x0093/3/10 == [0, 0, 128, 63] $ python -m cpppo.server.enip.client --print Motor_Velocity Motor_Velocity == [1.0]: 'OK'
To access Get Attribute data with CIP type conversion, use
cpppo.server.enip.get_attribute
’s proxy
classes, instead.
Specify a different local interface and/or port to connect to (default is :44818):
-a|--address [<interface>][:<port>]
On Windows systems, you must specify an actual interface. For example, if you started the
cpppo.server.enip simulator above (running on the all interfaces by default), use --address
localhost
.
Select the UDP/IP network protocol and optional “broadcast” support. Generally, EtherNet/IP CIP devices support UDP/IP only for some basic requests such as List Services, List Identity and List Interfaces:
-u|--udp -b|--broadcast
Send List Identity/Services/Interfaces requests:
-i|--list-identity -s|--list-services -I|--list-interfaces
For example, to find the Identity of all of the EtherNet/IP CIP devices on a local LAN with broadcast address 192.168.1.255 (that respond to broadcast List Identity via UDP/IP):
$ python -m cpppo.server.enip.client --udp --broadcast --list-identity -a 192.168.1.255 List Identity 0 from ('192.168.1.5', 44818): { "count": 1, "item[0].length": 58, "item[0].identity_object.sin_addr": "192.168.1.5", "item[0].identity_object.status_word": 48, "item[0].identity_object.vendor_id": 1, "item[0].identity_object.product_name": "1769-L18ER/A LOGIX5318ER", "item[0].identity_object.sin_port": 44818, "item[0].identity_object.state": 3, "item[0].identity_object.version": 1, "item[0].identity_object.device_type": 14, "item[0].identity_object.sin_family": 2, "item[0].identity_object.serial_number": 1615052645, "item[0].identity_object.product_code": 154, "item[0].identity_object.product_revision": 2837, "item[0].type_id": 12 } List Identity 1 from ('192.168.1.4', 44818): { "count": 1, "item[0].length": 63, "item[0].identity_object.sin_addr": "192.168.1.4", "item[0].identity_object.status_word": 48, "item[0].identity_object.vendor_id": 1, "item[0].identity_object.product_name": "1769-L23E-QBFC1 Ethernet Port", "item[0].identity_object.sin_port": 44818, "item[0].identity_object.state": 3, "item[0].identity_object.version": 1, "item[0].identity_object.device_type": 12, "item[0].identity_object.sin_family": 2, "item[0].identity_object.serial_number": 3223288659, "item[0].identity_object.product_code": 191, "item[0].identity_object.product_revision": 3092, "item[0].type_id": 12 } List Identity 2 from ('192.168.1.3', 44818): { "count": 1, "item[0].length": 53, "item[0].identity_object.sin_addr": "192.168.1.3", "item[0].identity_object.status_word": 4, "item[0].identity_object.vendor_id": 1, "item[0].identity_object.product_name": "1766-L32BXBA A/7.00", "item[0].identity_object.sin_port": 44818, "item[0].identity_object.state": 0, "item[0].identity_object.version": 1, "item[0].identity_object.device_type": 14, "item[0].identity_object.sin_family": 2, "item[0].identity_object.serial_number": 1078923367, "item[0].identity_object.product_code": 90, "item[0].identity_object.product_revision": 1793, "item[0].type_id": 12 } List Identity 3 from ('192.168.1.2', 44818): { "count": 1, "item[0].length": 52, "item[0].identity_object.sin_addr": "192.168.1.2", "item[0].identity_object.status_word": 4, "item[0].identity_object.vendor_id": 1, "item[0].identity_object.product_name": "1763-L16DWD B/7.00", "item[0].identity_object.sin_port": 44818, "item[0].identity_object.state": 0, "item[0].identity_object.version": 1, "item[0].identity_object.device_type": 12, "item[0].identity_object.sin_family": 2, "item[0].identity_object.serial_number": 1929488436, "item[0].identity_object.product_code": 185, "item[0].identity_object.product_revision": 1794, "item[0].type_id": 12 }
Sends certain “Legacy” EtherNet/IP CIP requests:
-L|--legacy <command>
Presently, only the following Legacy commands are implemented:
Command | Description |
---|---|
0x0001 | Returns some of the same network information as List Identity |
This command is not documented, and is not implemented on all types of devices
IP | Device | Product Name |
---|---|---|
192.168.1.2 | MicroLogix 1100 | 1763-L16DWD B/7.00 |
192.168.1.3 | MicroLogix 1400 | 1766-L32BXBA A/7.00 |
192.168.1.4 | CompactLogix | 1769-L23E-QBFC1 Ethernet Port |
192.168.1.5 | CompactLogix | 1769-L18ER/A LOGIX5318ER |
$ python -m cpppo.server.enip.client --udp --broadcast --legacy 0x0001 -a 192.168.1.255 Legacy 0x0001 0 from ('192.168.1.3', 44818): { "count": 1, "item[0].legacy_CPF_0x0001.sin_addr": "192.168.1.3", "item[0].legacy_CPF_0x0001.unknown_1": 0, "item[0].legacy_CPF_0x0001.sin_port": 44818, "item[0].legacy_CPF_0x0001.version": 1, "item[0].legacy_CPF_0x0001.sin_family": 2, "item[0].legacy_CPF_0x0001.ip_address": "192.168.1.3", "item[0].length": 36, "item[0].type_id": 1 } Legacy 0x0001 1 from ('192.168.1.5', 44818): { "peer": [ "192.168.1.5", 44818 ], "enip.status": 1, "enip.sender_context.input": "array('c', '\\x00\\x00\\x00\\x00\\x00\\x00\\x00\\x00')", "enip.session_handle": 0, "enip.length": 0, "enip.command": 1, "enip.options": 0 } Legacy 0x0001 2 from ('192.168.1.4', 44818): { "count": 1, "item[0].legacy_CPF_0x0001.sin_addr": "192.168.1.4", "item[0].legacy_CPF_0x0001.unknown_1": 0, "item[0].legacy_CPF_0x0001.sin_port": 44818, "item[0].legacy_CPF_0x0001.version": 1, "item[0].legacy_CPF_0x0001.sin_family": 2, "item[0].legacy_CPF_0x0001.ip_address": "192.168.1.4", "item[0].length": 36, "item[0].type_id": 1 } Legacy 0x0001 3 from ('192.168.1.2', 44818): { "count": 1, "item[0].legacy_CPF_0x0001.sin_addr": "192.168.1.2", "item[0].legacy_CPF_0x0001.unknown_1": 0, "item[0].legacy_CPF_0x0001.sin_port": 44818, "item[0].legacy_CPF_0x0001.version": 1, "item[0].legacy_CPF_0x0001.sin_family": 2, "item[0].legacy_CPF_0x0001.ip_address": "192.168.1.2", "item[0].length": 36, "item[0].type_id": 1 }
Change the verbosity (supply more to increase further):
-v[vv...]|--verbose
Change the default response timeout
-t|--timeout #
Specify a number of times to repeat the specified operations:
-r|--repeat #
To specify an Unconnected Send route_path
(other than the default backplane port 0, ‘1/0’ or
‘[{“port”: 1, “link”: 0}]’, which is a guess at the location of a *Logix controller in a typical
backplane), provide one in short <port>/<link> or JSON format. It must be a list containing one
dict specifying a port
and link
value. The port
is either an 8- or 16-bit number, and
link
is typically in the range 0-15 (a backplane slot) or an IP address. A string with a ‘/’
in it is parsed as <port>/<link>. If a only single route_path
element is intended, the JSON
array notation is optional:
--route-path '[{"port": 1, "link": 0}]' # backplane, slot 0 --route-path '{"port": 1, "link": 0}' # '' --route-path '1/0' # ''
Complex multi-segment route-paths must be specified in a JSON list. For example, to route via an EtherNet/IP module in backplane slot 3, and then out its second Ethernet port to address 1.2.3.4:
--route-path '["1/3",{"port":2,"link":"1.2.3.4"}]'# backplane slot 3, --route-path '["1/3","2/1.2.3.4"]' # then second port and IP 1.2.3.4
To specify no route_path
, use 0 or false (usually only in concert with –send-path=”, or just
use -S):
--route-path false
If a simple EtherNet/IP CIP device doesn’t support routing of message to
other CIP devices, and hence supports no Message Router Object, an empty
send-path may be supplied Normally, this also implies no route-path, so is
usually used in combination with --route-path=false
. This can be used to
prevent the issuance of Unconnected Send Service encapsulation, which “Only
originating devices and devices that route between links need to implement”
(see The CIP Networks Library, Vol 1, Table 3-5.8). Also avoid use of
--multiple
, as these devices do not generally accept Multiple Service
Packet requests, either.
Therefore, to communicate with simple, non-routing CIP devices (eg. AB
PowerFlex, …), use -S
or --simple
, or explicitly:
--send-path='' --route-path=false
Alternatively, to easily specify use of no routing Unconnected Send encapsulation in requests:
-S|--simple
Specify timeout_ticks
(default: 157 * 32ms == 5s.)
--timeout-ticks 63 # ~2s (if ticks == 32ms)
Specify the tick duration to use, when computing the actual timeout from timeout_ticks
. Each
tick has a duration from 1 to 32,768 milliseconds, computed as 2 ** <priority_tick_time>
milliseconds.
--priority-time-tick 0 # Set 1ms. ticks
To send log output to a file (limited to 10MB, rotates through 5 copies):
-l|--log <file>
To print a summary of PLC I/O to stdout, use --print
. Perhaps
surprisingly, unless you provide a --print
or -v
option, you will see no
output from the python -m cpppo.server.enip.client
or enip_client
command, at all. The I/O operations will be performed, however:
-p|--print --no-print (the default)
To force use of the Multiple Service Packet request, which carries multiple Read/Write Tag [Fragmented] requests in a single EtherNet/IP CIP I/O operation (default is to issue each request as a separate I/O operation):
-m|--multiple
To force the client to use plain Read/Write Tag commands (instead of the Fragmented commands, which are the default):
-n|--no-fragment
You may specify as many tags as you like on the command line; at least one is required. An optional register (range) can be specified (default is register 0):
<tag> <tag>[<reg>] <tag>[<reg>-<reg>] # eg. SCADA SCADA[1] SCADA[1-10]
Writing is supported; the number of values must exactly match the data specified register range:
<tag>=<value> # scalar, eg. SCADA=1 <tag>[<reg>-<reg>]=<value>,<value>,... # vector range <tag>[<reg>]=<value> # single element of a vector <tag>[<reg>-<reg>]=(DINT)<value>,<value> # cast to SINT/INT/DINT/REAL/BOOL/SSTRING/STRING
By default, if any <value> contains a ‘.’ (eg. ‘9.9,10’), all values are deemed to be REAL; otherwise, they are integers and are assumed to be type INT. To force a specific type (and limit the values to the appropriate value range), you may specify a “cast” to a specific type, eg. ‘TAG[4-6]=(DINT)1,2,3’. The types SINT, INT, DINT, REAL, BOOL, SSTRING and STRING are supported.
In addition to symbolic Tag addressing, numeric Class/Instance/Attribute addressing is available. A Class, Instance and Attribute address values are in decimal by default, but hexadecimal, octal etc. are available using escapes, eg. 26 == 0x1A == 0o49 == 0b100110:
@<class>/<instance>/<attribute> # read a scalar, eg. @0x1FF/01/0x1A @<class>/<instance>/<attribute>[99]=1 # write element, eg. @511/01/26=1
See further details of addressing cpppo.server.enip.client
’s
parse_operations
below.
Dispatching a multitude of EtherNet/IP CIP I/O operations to a Controller
(with our without pipelining) is very simple. If you don’t need to see the
results of each operation as they occur, or just want to ensure that they
succeeded, you can use connector.process
(see cpppo/server/enip/client/io_example.py
):
host = 'localhost' # Controller IP address port = address[1] # default is port 44818 depth = 1 # Allow 1 transaction in-flight multiple = 0 # Don't use Multiple Service Packet fragment = False # Don't force Read/Write Tag Fragmented timeout = 1.0 # Any PLC I/O fails if it takes > 1s printing = True # Print a summary of I/O tags = ["Tag[0-9]+16=(DINT)4,5,6,7,8,9", "@0x2/1/1", "Tag[3-5]"] with client.connector( host=host, port=port, timeout=timeout ) as connection: operations = client.parse_operations( tags ) failures,transactions = connection.process( operations=operations, depth=depth, multiple=multiple, fragment=fragment, printing=printing, timeout=timeout ) sys.exit( 1 if failures else 0 )
Try it out by starting up a simulated Controller:
$ python -m cpppo.server.enip Tag=DINT[10] & $ python -m cpppo.server.enip.io
The API is able to “pipeline” requests – issue multiple requests on the wire, while simultaneously harvesting the results of prior requests. This is absolutely necessary in order to obtain reasonable I/O performance over high-latency links (eg. via Satellite).
To use pipelining, create a client.connector
which establishes and
registers a CIP connection to a Controller. Then, produce a sequence of
operations (eg, parsed from “Tag[0-9]+16=(DINT)5,6,7,8,9” or from numeric
Class, Instance and Attribute numbers “@2/1/1” ), and dispatch the requests
using connector methods .pipeline
or .synchronous
(to access the details
of the requests and the harvested replies), or .process
to simply get a
summary of I/O failures and total transactions.
More advanced API methods allow you to access the stream of I/O in full
detail, as responses are received. To issue command synchronously use
connector.synchronous
, and to “pipeline” the requests (have multiple
requests issued and “in flight” simultaneously), use connector.pipeline
(see cpppo/server/enip/client/thruput.py
)
ap = argparse.ArgumentParser() ap.add_argument( '-d', '--depth', default=0, help="Pipelining depth" ) ap.add_argument( '-m', '--multiple', default=0, help="Multiple Service Packet size limit" ) ap.add_argument( '-r', '--repeat', default=1, help="Repeat requests this many times" ) ap.add_argument( '-a', '--address', default='localhost', help="Hostname of target Controller" ) ap.add_argument( '-t', '--timeout', default=None, help="I/O timeout seconds (default: None)" ) ap.add_argument( 'tags', nargs='+', help="Tags to read/write" ) args = ap.parse_args() depth = int( args.depth ) multiple = int( args.multiple ) repeat = int( args.repeat ) operations = client.parse_operations( args.tags * repeat ) timeout = None if args.timeout is not None: timeout = float( args.timeout ) with client.connector( host=args.address, timeout=timeout ) as conn: start = cpppo.timer() num,idx = -1,-1 for num,(idx,dsc,op,rpy,sts,val) in enumerate( conn.pipeline( operations=operations, depth=depth, multiple=multiple, timeout=timeout )): print( "%s: %3d: %s" % ( timestamp(), idx, val )) elapsed = cpppo.timer() - start print( "%3d operations using %3d requests in %7.2fs at pipeline depth %2s; %5.1f TPS" % ( num+1, idx+1, elapsed, args.depth, num / elapsed ))
Fire up a simulator with a few tags, preferably on a host with a high network latency relative to your current host:
$ ssh <hostname> $ python -m cpppo.server.enip --print -v Volume=REAL Temperature=REAL
Then, test the thruput TPS (Transactions Per Second) with various pipeline
--depth
and Multiple Service Packet size settings.
Try it first with the default depth of 0 (no pipelining). This is the
“native” request-by-request thruput of the network route and device:
$ python -m cpppo.server.enip.thruput -a <hostname> "Volume" "Temperature" \ --repeat 25
Then try it with aggressive pipelining (the longer the “ping” time between
the two hosts, the more --depth
you could benefit from):
... --repeat 25 --depth 20
Adding --multiple <size>
allows cpppo to aggregate multiple Tag I/O
requests into a single Multiple Service Packet, reducing the number of
EtherNet/IP CIP requests:
... --repeat 25 --depth 20 --multiple 250
The base class client.client
implements all the basic I/O capabilities
for pipeline-capable TCP/IP and UDP/IP I/O with EtherNet/IP CIP devices.
Keyword | Description |
---|---|
host | A cpppo.server.enip.get_attribute proxy derived class |
port | Target port (if not 44818) |
timeout | Optional timeout on socket.create_connection
|
dialect | An EtherNet/IP CIP dialect, if not logix.Logix |
udp (False) | Establishes a UDP/IP socket to use for request (eg. List Identity) |
broadcast (False) | Avoids connecting UDP/IP sockets; may receive many replies |
source_address | Bind to a specific local interface (Default: 0.0.0.0:0) |
profiler | If using a Python profiler, provide it to disable around I/O code |
Once connectivity is established, a sequence of CIP requests can be issued
using the the methods .read
, .write
, .list_identity
, etc.
Later, .readble
can report if incoming data is available. Then, the
connection instance can be used as an iterable; next( connection )
will
return any response available. This response will include a peer
entry
indicating the reported peer IP address and port (especially useful for
broadcast UDP/IP requests).
These facilities are used extensively in the client.connector
derived
class to implementing request pipelining.
Note that not all requests can be issued over UDP/IP channels; consult the
EtherNet/IP CIP literature to discover which may be used. The List
Services/Identity/Interfaces requests are known to work, and are useful for
discovering what EtherNet/IP CIP devices are available in a LAN using
UDP/IP broadcast addresses; setting both the udp
and broadcast
parameters to True
.
If multiple local interfaces are provided, it is possible that you may with
to only broadcast on a certain interface (eg. on the “Plant” LAN interface,
not the “Business” WAN interface). Use source_address
to specify a local
interface’s IP address to bind to, before connecting or sending requests.
Accepts IP addresses and optionally a port number in “1.2.3.4:12345” form.
Remember that UDP/IP packets sent using broadcast addresses will not be received by a server bound to a specific local interface address. Therefore, if you wish to find all EtherNet/IP CIP servers in your LAN including the simulated ones running on your host, you may wish to start a simulated server on a local interface, eg. 192.168.0.52:
$ python -m cpppo.server.enip -vv --address 192.168.1.5 SCADA=INT[100]
Then, you might issue a broadcast from this (or another) host on the network, expecting a response from your simulator, but not receiving one:
$ python -m cpppo.server.enip.list_services -vv --udp --broadcast \\ --source 192.168.1.5 --address 192.168.1.255 05-25 15:51:02.044 MainThread enip.cli DETAIL __init__ Connect: UPD/IP to ('192.168.1.255', 44818) via ('192.168.1.7', 0) broadcast 05-25 15:51:02.072 MainThread enip.cli DETAIL cip_send Client CIP Send: { "enip.status": 0, "enip.sender_context.input": "bytearray(b'\\x00\\x00\\x00\\x00\\x00\\x00\\x00\\x00')", "enip.session_handle": 0, "enip.CIP.list_services": {}, "enip.options": 0 } 05-25 15:51:02.073 MainThread enip.cli DETAIL cip_send Client CIP Send: { "enip.status": 0, "enip.sender_context.input": "bytearray(b'\\x00\\x00\\x00\\x00\\x00\\x00\\x00\\x00')", "enip.session_handle": 0, "enip.CIP.list_identity": {}, "enip.options": 0 } $
Why? Because you have bound the server to specific IP address, 192.168.1.5. If you instead bind it to “all” interfaces (thus, at no specific IP address) using any of the following incantations:
$ python -m cpppo.server.enip -vv SCADA=INT[100] $ python -m cpppo.server.enip -vv --address '' SCADA=INT[100] $ python -m cpppo.server.enip -vv --address 0.0.0.0 SCADA=INT[100]
or if you bind it to the “broadcast” address of the specific interface you wish to use:
$ python -m cpppo.server.enip -vv --address 192.168.1.255 SCADA=INT[100]
then it will receive the broadcast packets, and respond appropriately.
Register a TCP/IP EtherNet/IP CIP connection to a Controller, allowing the holder to issue requests and receive replies as they are available, as an iterable sequence. Support Read/Write Tag [Fragmented], Get/Set Attribute [All], and Multiple Service Packet requests, via CIP “Unconnected Send”.
Establish exclusive access using a python context operation:
from cpppo.server.enip import client with client.connector( host="some_controller" ) as conn: ...
To establish a UDP/IP connected (optionally broadcast capable) connection:
from cpppo.server.enip import client with client.connector( host="some_controller", udp=True, broadcast=True ) as conn:
UDP/IP connections do not issue CIP Register requests (as they are only
supported via TCP/IP). Generally, these are only useful for issuing List
Identity, List Services or List Interfaces requests. If broadcast (and a
“broadcast” IP address such as 255.255.255.255 is used), then multiple
responses should be expected; the default cpppo.server.enip.client
module
entrypoint will wait for the full duration of the specified timeout
for
responses.
Takes a sequence of Tag-based or numeric CIP Attribute descriptions, and
converts them to operations suitable for use with a client.connector
.
For example:
>>> from cpppo.server.enip include client >>> list( client.parse_operations( [ "A_Tag[1-2]=(REAL)111,222" ] )) [{ 'data': [111.0, 222.0], 'elements': 2, 'method': 'write', 'path': [{'symbolic': 'A_Tag'},{'element': 1}], 'tag_type': 202 }]
A symbolic Tag is assumed, but an @
indicates a numeric CIP address,
with each segment’s meaning defaulting to:
@<class>/<instance>/<attribute>/<element>
More complex non-default numeric addressing is also supported, allowing
access to Assembly instances, Connections, etc. For example, to address an
Assembly (class 0x04), Instance 5, Connection 100, use JSON encoding for
each numeric element that doesn’t match the default sequence of <class>
,
<instance>
, … So, to specify that the third element is a Connection
(instead of an Attribute) number, any of these are equivalent:
@4/5/{"connection":100} @0x04/5/{"connection":100} @{"class":4}/5/{"connection":100}
The following path components are supported:
Component | Description |
---|---|
class | 8/16-bit Class number |
instance | 8/16-bit Instance number |
attribute | 8/16-bit Attribute number |
element | 8/16/32-bit Element number |
connection | 8/16-bit Connection number |
symbolic | ISO-8859-1 Symbolic Tag name |
port,link | Port number, Link number or IP address |
(typically valid only in route_path ) |
The number of elements in a request is normally deduced from an index range; for example, to specify 10 elements:
Tag[1].SubTag[0-9]
To manually specify a number of elements in a request, append an *###
to
the request:
Tag[1].SubTag[0]*10
Issues a sequence of operations to a Controller in synchronous
fashion
(one at a time, waiting for the response before issuing the next command)
or in pipeline
fashion, issuing multiple requests before asynchronous
waiting for responses.
Automatically choose synchronous
or pipeline
behaviour by using
operate
, which also optionally chains the results through validate
to
log/print a summary of I/O operations and fill in the yielded data value
for all Write Tag operations (instead of just signalling success with a
True
value).
Automatically bundles requests up into appropriately sized Multiple Service Packets (if desired), and pipelines multiple requests in-flight simultaneously over the TCP/IP connection.
Must be provided a sequence of ‘operations’ to perform, each as a dict containing:
Key | Description |
---|---|
method | ‘read’, ‘write’, ‘set/get_attribute_single’, ‘get_attributes_all’ |
path | The operation’s path, eg [{“class”: 2},{“instance”: 1},…] |
offset | A byte offset, for Fragmented read/write |
elements | The number of elements to read/write |
tag_type | The EtherNet/IP type, eg. 0x00ca for “REAL” |
data | For ‘write’, ‘set_attribute…’; the sequence of data to write |
Use client.parse_operations
to convert a sequence of simple Tag assignments
to a sequence suitable for ‘operations’:
operations = client.parse_operations( ["Tag[8-9]=88,99", "Tag[0-10]"] )
The full set of keywords to .synchronous
are:
Keyword | Description |
---|---|
operations | A sequence of operations |
index | The starting index used for “sender_context” |
fragment | If True, forces use of Fragmented read/write |
multiple | If >0, uses Multiple Service Packets of up to this many bytes |
timeout | A timeout, in seconds. |
The .pipeline
method also defaults to have 1 I/O operation in-flight:
Keyword | Description |
---|---|
depth | The number of outstanding requests (default: 1) |
And .operate
method adds these defaults:
Keyword | Description |
---|---|
depth | The number of outstanding requests (default: 0) |
validating | Log summary of I/O operations, fill in Tag Write values (default: False) |
printing | Also print a summary of I/O operations to stdout (default: False) |
Invoking .pipeline
, .synchronous
or operate
on a sequence of
operations yields a (…, (<idx>,<dsc>,<req>,<rpy>,<sts>,<val>), …)
sequence, as replies are received. If .pipeline=/
.operate= is used,
there may be up to depth
requests in-flight as replies are yielded; if
.synchronous
, then each reply is yielded before the next request is
issued. The 6-tuples yielded are comprised of these items:
Item | Description |
---|---|
0 - idx | The index of the operation, sent as the “sender_context” |
1 - dsc | A description of the operation |
2 - req | The request |
3 - rpy | The reply |
4 - sts | The status value (eg. 0x00) or tuple (eg. (0xff,(0x1234)) ) |
5 - val | The reply value (None, if reply was in error) |
The structure of the code to connect to a Controller host and process a
sequence of operations (with a default pipelining depth
of 1 request
in-flight) is simply:
with client.connector( host=... ) as conn: for idx,dsc,req,rpy,sts,val in conn.pipeline( operations=... ): ...
Issues a sequence of operations to a Controller either synchronously or
with pipelining, and .results
yields only the results of the operations
as a sequence, as they arrive (on-demand, as a generator). None
indicates failure. The .process
API checks all result values for
failures (any result values which are None
), and returns the tuple
(<failures>,[…, <result>, …]).
Directly issue read/write requests by supplying all the details; a dict
describing the request is returned. If send
is True
(the default), the
request is also issued on the wire using .unconnected_send
.
with client.connector( host=... ) as conn: req = conn.read( "Tag[0-1]" )
Later, harvest the results of the read/write request issued on conn
using
next(...)
on the conn (it is iterable, and returns replies as they are
ready to be received). Once the response is ready, a fully encapsulated
response payload will be returned:
assert conn.readable( timeout=1.0 ), "Failed to receive reply" rpy = next( conn )
This fully encapsulated response carries the EtherNet/IP frame and status,
the CIP frame, its CPF frames with its Unconnected Send payload, and
finally the encapsulated request; the Read/Write Tag [Fragmented] payload
(in a cpppo.dotdict
, a dict
that understands dotted keys accessible as
attributes, slightly formatted here for readability):
>>> for k,v in rpy.items(): ... print k,v ... enip.status 0 enip.sender_context.input array('c', '\x00\x00\x00\x00\x00\x00\x00\x00') enip.session_handle 297965756 enip.length 20 enip.command 111 enip.input array('c', '\x00\x00\x00\x00\x00\x00\x02\x00\x00\x00\x00\x00\xb2\x00\x04\x00\xd3\x00\x00\x00') enip.options 0 enip.CIP.send_data.interface 0 enip.CIP.send_data.timeout 0 enip.CIP.send_data.CPF.count 2 enip.CIP.send_data.CPF.item[0].length 0 enip.CIP.send_data.CPF.item[0].type_id 0 enip.CIP.send_data.CPF.item[1].length 4 enip.CIP.send_data.CPF.item[1].type_id 178 enip.CIP.send_data.CPF.item[1].unconnected_send.request.status 0 enip.CIP.send_data.CPF.item[1].unconnected_send.request.input array('c', '\xd3\x00\x00\x00') enip.CIP.send_data.CPF.item[1].unconnected_send.request.service 211 enip.CIP.send_data.CPF.item[1].unconnected_send.request.write_frag True enip.CIP.send_data.CPF.item[1].unconnected_send.request.status_ext.size 0 >>>
The response payload is highly variable (eg. may contain further
encapsulations such as Multiple Service Packet framing), so it is
recommended that you use the .synchronous
, .pipeline
, .results
, or
.process
interfaces instead (unless you are one of the 3 people that
deeply understands the exquisite details of the EtherNet/IP CIP protocol).
These generate, parse and discard all the appropriate levels of
encapsulation framing.
The Get Attribute[s] Single/All operations are also supported. These are used to access the raw data in arbitrary Attributes of CIP Objects. This data is always presented as raw 8-bit SINT data.
You can use these methods directly (as with .write
, above, and harvest
the results manually), or you can modify a sequence of operations from
client.parse_operations
, and gain access to the convenience and
efficiency of client.connector
’s .pipeline
to issue and process the
stream of EtherNet/IP CIP requests.
Create a simple generator wrapper around client.parse_operations
, which
substitutes get_attributes_all
or get_attribute_single
as appropriate.
Use numeric addressing to the Instance or Attribute level,
eg. @<class>/<instance>
or @<class>/<instance>/<attribute>
. One is
implemented in cpppo/server/enip/get_attribute.py
:
from cpppo.server.enip.get_attribute import attribute_operations timeout = None # Wait forever, or <float> seconds depth = 0 # No pipelining, or <int> in-flight with client.connector( host=args.address, timeout=timeout ) as conn: for idx,dsc,op,rpy,sts,val in conn.pipeline( operations=attribute_operations( tags ), depth=depth, multiple=False, timeout=timeout ):
Here is an example of getting all the raw Attribute data from the CIP Identity object (Class 1, Instance 1) of a Controller (Get Attributes All, and Get Attribute Single of Class 1, Instance 1, Attribute 7):
$ python -m cpppo.server.enip.get_attribute --depth 3 -v '@1/1' '@1/1/7' 2015-04-21 14:51:14.633: 0: Single G_A_A @0x0001/1 == [1, 0, 14, 0, 54, \ 0, 20, 11, 96, 49, 26, 6, 108, 0, 20, 49, 55, 53, 54, 45, 76, 54, 49, 47, \ 66, 32, 76, 79, 71, 73, 88, 53, 53, 54, 49, 255, 0, 0, 0] 2015-04-21 14:51:14.645: 1: Single G_A_S @0x0001/1/7 == [20, 49, 55, 53, \ 54, 45, 76, 54, 49, 47, 66, 32, 76, 79, 71, 73, 88, 53, 53, 54, 49]
Decoding the Identity Attribute 7 CIP STRING as ASCII data yields (the first character is the length: 20 decimal, or 14 hex):
$ python >>> ''.join( chr( x ) for x in [ 20, 49, 55, 53, 54, 45, 76, 54, 49, 47, 66, 32, 76, 79, 71, 73, 88, 53, 53, 54, 49]) '\x141756-L61/B LOGIX5561'
To access Get Attribute data with CIP type conversion, use
cpppo.server.enip.get_attribute
’s proxy
classes, instead.
To use Set Attribute Single, provide an array of CIP USINT
or SINT
values appropriate to the size of the target Attribute. Alternatively,
provide a tag_type
number corresponding to the CIP data type. If the
tag_type is supported by cpppo.server.enip.parser
’s typed_data
implementation, we’ll convert it to USINT
for you ([U]SINT
, [U]INT
,
[U]DINT
, REAL
, SSTRING
and STRING
are presently supported).
Typically, you will invoke client.connector.set_attribute_single
indirectly by providing attribute_operations
a sequence containing tag
operation such as @<class>/<instance>/<attribute>=(REAL)1.1
(see
get_attribute_single
, above.) If you start the enip_server
... FLOAT@22/1/3=REAL
command, above, and then run:
$ python -m cpppo.server.enip.get_attribute '@22/1/3=(REAL)1.0' '@22/1/3' Mon Feb 22 15:29:51 2016: 0: Single S_A_S @0x0016/1/3 == True Mon Feb 22 15:29:51 2016: 1: Single G_A_S @0x0016/1/3 == [0, 0, 128, 63]
Confirm that you wrote the correct floating-ponit value:
$ python -m cpppo.server.enip.client 'FLOAT' FLOAT == [1.0]: 'OK'
These methods issue List Identity, List Services and List Interfaces
requests, valid on either UDP/IP or TCP/IP connections (or via UDP/IP
broadcast). The response(s) may be harvested by awaiting for incoming
activity on the connection. The cpppo.server.enip.list_identity_simple
example broadcasts a UDP/IP List Identity request to the local LAN,
awaiting all responses until timeout expires without activity:
from __future__ import print_function import sys from cpppo.server import enip from cpppo.server.enip import client timeout = 1.0 host = sys.argv[1] if sys.argv[1:] else '255.255.255.255' with client.client( host=host, udp=True, broadcast=True ) as conn: conn.list_identity( timeout=timeout ) while True: response,elapsed = client.await_response( conn, timeout=timeout ) if response: print( enip.enip_format( response )) else: break # No response (None) w'in timeout or EOF ({})
See cpppo.server.enip.client
for a more advanced approach which returns
only the relevant List Identity or List Services payload from the response,
and enforces a total timeout, rather than a per-response timeout.
The cpppo.server.enip.list_services
module entrypoint provides a more
complete CLI interface for generating and harvesting List Services and List
Identity responses:
$ python -m cpppo.server.enip.list_services --help usage: list_services.py [-h] [-v] [-a ADDRESS] [-u] [-b] [--identity] [--interfaces] [-t TIMEOUT] List Services (by default) on an EtherNet/IP CIP Server. optional arguments: -h, --help show this help message and exit -v, --verbose Display logging information. -a ADDRESS, --address ADDRESS EtherNet/IP interface[:port] to connect to (default: ':44818') -u, --udp Use UDP/IP queries (default: False) -b, --broadcast Allow multiple peers, and use of broadcast address (default: False) -i, --list-identity List Identity (default: False) -I, --list-interfaces List Interfaces (default: False) -t TIMEOUT, --timeout TIMEOUT EtherNet/IP timeout (default: 5s)
It always requests List Services, and (optionally) List Identity, List Interfaces. By default, it sends the requests unicast via TCP/IP, but can optionally send the requests via unicast or broadcast UDP/IP. The full content of each EtherNet/IP CIP response is printed.
To obtain responses from all EtherNet/IP CIP devices on the local LAN with broadcast address 192.168.0.255:
$ python -m cpppo.server.enip.list_services --udp --broadcast \ --list-identity -a 192.168.0.255 { "peer": [ "192.168.0.201", 44818 ], "enip.status": 0, "enip.sender_context.input": "array('c', '\\x00\\x00\\x00\\x00\\x00\\x00\\x00\\x00')", "enip.session_handle": 0, "enip.length": 25, "enip.CIP.list_services.CPF.count": 1, "enip.CIP.list_services.CPF.item[0].communications_service.capability": 288, "enip.CIP.list_services.CPF.item[0].communications_service.service_name": "Communications", "enip.CIP.list_services.CPF.item[0].communications_service.version": 1, "enip.CIP.list_services.CPF.item[0].length": 19, "enip.CIP.list_services.CPF.item[0].type_id": 256, "enip.command": 4, "enip.input": "array('c', '\\x01\\x00\\x00\\x01\\x13\\x00\\x01\\x00 \\x01Communications\\x00')", "enip.options": 0 } { "peer": [ "192.168.0.201", 44818 ], "enip.status": 0, "enip.sender_context.input": "array('c', '\\x00\\x00\\x00\\x00\\x00\\x00\\x00\\x00')", "enip.session_handle": 0, "enip.length": 60, "enip.CIP.list_identity.CPF.count": 1, "enip.CIP.list_identity.CPF.item[0].length": 54, "enip.CIP.list_identity.CPF.item[0].identity_object.sin_addr": "192.168.0.201", "enip.CIP.list_identity.CPF.item[0].identity_object.status_word": 12640, "enip.CIP.list_identity.CPF.item[0].identity_object.vendor_id": 1, "enip.CIP.list_identity.CPF.item[0].identity_object.product_name": "1756-L61/C LOGIX5561", "enip.CIP.list_identity.CPF.item[0].identity_object.sin_port": 44818, "enip.CIP.list_identity.CPF.item[0].identity_object.state": 255, "enip.CIP.list_identity.CPF.item[0].identity_object.version": 1, "enip.CIP.list_identity.CPF.item[0].identity_object.device_type": 14, "enip.CIP.list_identity.CPF.item[0].identity_object.sin_family": 2, "enip.CIP.list_identity.CPF.item[0].identity_object.serial_number": 7079450, "enip.CIP.list_identity.CPF.item[0].identity_object.product_code": 54, "enip.CIP.list_identity.CPF.item[0].identity_object.product_revision": 2836, "enip.CIP.list_identity.CPF.item[0].type_id": 12, "enip.command": 99, "enip.input": "array('c', '\\x01...\\x141756-L61/C LOGIX5561\\xff')", "enip.options": 0 }
Many devices such as Rockwell MicroLogix, Allen-Bradley PowerFlex, etc. that advertise EtherNet/IP CIP protocol offer only very basic connectivity:
- No CIP “routing” capability, hence no Unconnected Send encapsulation, including route path or send path addressing.
- No “Logix” style Read/Write Tag [Fragmented]; only Get/Set Attribute.
- Only raw 8-bit CIP SINT data; CIP data type transformations done by client
Therefore, a set of APIs are provided to “proxy” these devices, providing higher level data types and maintenance of EtherNet/IP CIP connectivity. In order to retain high thruput, the API maintains the ability to “pipeline” requests over high-latency links.
Access an EtherNet/IP CIP device using either generic Get Attributes All/Single, or *Logix Read Tag [Fragmented] services, as desired. Data is delivered converted to target format.
To create a “proxy” for a simple (non-routing) remote EtherNet/IP CIP sensor
device, such as an A-B PowerFlex, with (for example) a CIP REAL
attribute
at Class 0x93, Instance 1, Attribute 10:
from cpppo.server.enip.get_attribute import proxy_simple class some_sensor( proxy_simple ): '''A simple (non-routing) CIP device with one parameter with a shortcut name: 'A Sensor Parameter' ''' PARAMETERS = dict( proxy_simple.PARAMETERS, a_sensor_parameter = proxy_simple.parameter( '@0x93/1/10', 'REAL', 'Hz' ), )
If you have an A-B PowerFlex handy, use your custom proxy
or
proxy_simple
class called some_sensor
defined above, and its “A Sensor
Parameter” attribute. Alternatively, just use the plain proxy
(if you
have a ControlLogix or CompactLogix), or proxy_simple
(if you have a
MicroLogix) classes in these examples, and use the “Product Name” attribute
(which reads the CIP SSTRING
at Class 1, Instance 1, Attribute 7: See
cpppo/server/enip/get_attribute.py
)
In your Python code, to access the parameter “A Sensor Parameter” from the
remote A-B PowerFlex device (the supplied name is transformed to
a_sensor_parameter
by lowering case and transforming ’ ’ to ‘_’, to check
for matching any proxy.PARAMETER
entry):
via = some_sensor( host="10.0.1.2" ) try: params = via.parameter_substitution( "A Sensor Parameter" ) value, = via.read( params ) except Exception as exc: logging.warning( "Access to remote CIP device failed: %s", exc ) via.close_gateway( exc=exc ) raise
There are several important things to note here:
- You can
.read
1 or more values. Here, we supply a single Pythonstr
, so theproxy.parameter_substitution
deduces that you want one named parameter value. Provide a sequence of attributes to read more than one. - The
.read
returns a sequence of all the requested values, so we use Pythontuple
assignment to unpack a sequence containing a single value, eg:variable, = [123]
- Upon the first error accessing and/or transforming a value from the
remote device, the Python generator will raise an exception. Whereever
in your code that you “reify” the generator’s values (access them and
assign them to local variables), you must trap any Exception and notify
the
get_attribute.proxy
by invoking.close_gateway
. This prepares theget_attribute.proxy
to re-open the connection for a future attempt to access the device.
A successful .read
(with no timeouts, no I/O errors) can return None,
instead of valid data, if the CIP device reports an error status code for a
request. This is only case where the results of a .read
will be “Falsey”
(evaluate False
in a boolean test). All successful reads of valid data
will return a non-empty list of results, and are “Truthy” (evalute
True
). Each returned value must be tested.
To guarantee that an Exception is raised if any result is not returned, you
can set .read
’s checking
parameter to True
:
via = some_sensor( host="10.0.1.2" ) try: # Will raise Exception (closing gateway) on any failure to get data params = via.parameter_substitution( "A Sensor Parameter" ) value, = via.read( params, checking=True ) except Exception as exc: via.close_gateway( exc ) raise # value is *always* guaranteed to be [<value>]
The .read
method (or its alias .write
) support writing to
CIP Attributes. Simply append an equals sign, a CIP type in
parentheses, and a comma-separated list of values to the
parameter or Attribute name.
# # Write a Motor Velocity to an AB PowerFlex AC Drive Controller # # python -m cpppo.server.enip.powerflex_motor_velocity @localhost 123.45 # # To start a simulator (a partial AB PowerFlex) on localhost suitable for writing: # # python -m cpppo.server.enip.poll_test # import logging import sys import time import traceback import cpppo #cpppo.log_cfg['level'] = logging.DETAIL logging.basicConfig( **cpppo.log_cfg ) #from cpppo.server.enip.get_attribute import proxy_simple as device # MicroLogix #from cpppo.server.enip.get_attribute import proxy as device # ControlLogix from cpppo.server.enip.ab import powerflex_750_series as device # PowerFlex 750 # Optionally specify Powerflex DNS name or IP address, prefixed with '@': host = 'localhost' if len( sys.argv ) > 1 and sys.argv[1].startswith( '@' ): host = sys.argv.pop( 1 )[1:] # Optionally specify velocity; defaults to 0: velocity = 0 if len( sys.argv ) > 1: velocity = float( sys.argv.pop( 1 )) param = 'Motor Velocity = (REAL)%s' % ( velocity ) try: via = device( host=host ) with via: # establish gateway, detects Exception (closing gateway) val, = via.write( via.parameter_substitution( param ), checking=True ) print( "%s: %-32s == %s" % ( time.ctime(), param, val )) except Exception as exc: logging.detail( "Exception writing Parameter %s: %s, %s", param, exc, traceback.format_exc() ) sys.exit( 1 )
If the target device understands only basic CIP I/O requests, or you wish to perform special
processing on the stream of operations generated from the supplied tags, you can specify the
proxy
with a specific operations_parser
. The default is to use client.parse_operations
if data types are provided, and get_attribute.attribute_operations
otherwise.
If we know we want to generate EtherNet/IP CIP Get/Set Attribute requests but we wish to pass
specific data types (eg. INT
), create the proxy_simple
device w/ an appropriate
operations_parser
parameter:
# # Basic CIP I/O Test # # Target Simulator: # python3 -m cpppo.server.enip -S -vv SCADA@0x4/0x96/3=INT[18] # import cpppo from cpppo.server.enip.get_attribute import ( attribute_operations, proxy_simple as device ) from cpppo.server.enip import client import logging cpppo.log_cfg['level'] = logging.DEBUG logging.basicConfig( **cpppo.log_cfg ) hostname = 'localhost' # Our target CIP Attribute contains a 36 bytes == 18 x INT value attribute = '@0x4/0x96/3' values = "512,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0" operations = [attribute + ' = (INT)' + values] print( "Raw operations: %r" % operations ) operations_parser = attribute_operations operations_out = list( operations_parser( operations )) assert operations_out == [{ 'method': 'set_attribute_single', 'path': [{'class': 4}, {'instance': 150}, {'attribute': 3}], 'tag_type': 195, 'data': [512, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0], 'elements': 18 }] # Force basic CIP Get/Set Attribute I/O operations via = device( hostname, operations_parser=operations_parser ) val, = via.write( operations )
There is a simple mechanism provided to ensure that all of the above
maintenance of the proxy
’s gateway occurs: the proxy
class provides a
Context Manager API, which ensures that the proxy
’s gateway is opened, and
that the proxy
’s .close_gateway
is invoked on any Exception that occurs
while reifying the generator returned by proxy.read
:
via = some_sensor( host="10.0.1.2" ) with via: params = via.parameter_substitution( "A Sensor Parameter" ) value, = via.read( params ) # value may be something like [1.23], or None if returned error status
Wherever in your code that you plan to use the results obtained from a
proxy, ensure that you enclose it in a with <proxy>:
block. You may even
call the .read
method elsewhere (it is already protected against
Exceptions raised during initial processing): just ensure that the context
manager is invoked before you begin to use the results, so that Exceptions
caused by I/O errors are properly captured:
from __future__ import print_function via = some_sensor( host="10.0.1.2" ) params = via.parameter_substitution( "A Sensor Parameter" ) reader = via.read( params ) # ... later ... with via: for value in reader: print( "Got: %r" % ( value ))
As soon as a proxy
’s gateway is opened, the .instance
attribute is
populated with the results of the device’s CIP “List Identity” response.
At any time, the proxy.__str__
method can be used to print the device
Identity’s Product Name, network address, and CIP session id.
The connection and List Identity request doesn’t occur ‘til the proxy
is
accessed using .read
, or the Context Manager is invoked using with
<proxy>:
from __future__ import print_function via = some_sensor( host="10.0.1.2" ) print( "Not yet connected: %s" % ( via )) params = via.parameter_substitution( "A Sensor Parameter" ) reader = via.read( params ) print( "Connected! %s" % ( via ))
Producing the output:
Not yet connected: None at None Connected! 1756-L61/C LOGIX5561 at localhost:44818[2206679763]
If you wish to avoid getting the device’s identity using CIP List Identity,
simply pass a product name string "Something"
(or a
cpppo.dotdict({"product_name":"Something"}))
) in the identity_default
parameter:
from __future__ import print_function via = proxy( host="localhost", identity_default="Something" ) print( "Not yet connected: %s" % ( via )) params = via.parameter_substitution( "Product Name" ) reader = via.read( params ) print( "Connected! %s" % ( via ))
This would produce something like:
Not yet connected: Something at None Connected! Something at localhost:44818[576509498]
If regular updates of values from an EtherNet/IP CIP device are required,
then the cpppo.server.enip.poll
API may be useful.
# # Poll a PowerFlex 750 series at IP (or DNS name) "<hostname>" (default: localhost) # # python -m cpppo.server.enip.poll_example <hostname> # # To start a simulator on localhost suitable for polling: # # python -m cpppo.server.enip.poll_test # import logging import sys import time import threading import cpppo #cpppo.log_cfg['level'] = logging.DETAIL logging.basicConfig( **cpppo.log_cfg ) from cpppo.server.enip import poll #from cpppo.server.enip.get_attribute import proxy_simple as device # MicroLogix #from cpppo.server.enip.get_attribute import proxy as device # ControlLogix from cpppo.server.enip.ab import powerflex_750_series as device # PowerFlex 750 # Device IP in 1st arg, or 'localhost' (run: python -m cpppo.server.enip.poll_test) hostname = sys.argv[1] if len( sys.argv ) > 1 else 'localhost' # Parameters valid for device; for *Logix, others, try: # params = [('@1/1/1','INT'),('@1/1/7','SSTRING')] params = [ "Motor Velocity", "Output Current" ] def failure( exc ): failure.string.append( str(exc) ) failure.string = [] # [ <exc>, ... ] def process( par, val ): process.values[par] = val process.done = False process.values = {} # { <parameter>: <value>, ... } poller = threading.Thread( target=poll.poll, kwargs={ 'proxy_class': device, 'address': (hostname, 44818), 'cycle': 1.0, 'timeout': 0.5, 'process': process, 'failure': failure, 'params': params, }) poller.start() # Monitor the process.values {} and failure.string [] (updated in another Thread) try: while True: while process.values: par,val = process.values.popitem() print( "%s: %16s == %r" % ( time.ctime(), par, val )) while failure.string: exc = failure.string.pop( 0 ) print( "%s: %s" %( time.ctime(), exc )) time.sleep( .1 ) finally: process.done = True poller.join()
If you start a (simulated) A-B PowerFlex (be prepared to stop and restart
it, to observe how the cpppo.server.enip.poll
API handles polling failures):
$ cpppo -m cpppo.server.enip.poll_test
and then in another terminal, start the (above) poll_example.py
(also
included in the cpppo
installation). You’ll see something like this (make
sure you stop/pause and then restart the poll_test.py
A-B PowerFlex
simulator during the test):
$ cpppo -m cpppo.server.enip.poll_example Wed Feb 3 11:47:58 2016: [Errno 61] Connection refused Wed Feb 3 11:47:59 2016: [Errno 61] Connection refused Wed Feb 3 11:48:00 2016: [Errno 61] Connection refused Wed Feb 3 11:48:03 2016: Motor Velocity == [789.010009765625] Wed Feb 3 11:48:03 2016: Output Current == [123.44999694824219] Wed Feb 3 11:48:04 2016: Motor Velocity == [789.010009765625] Wed Feb 3 11:48:04 2016: Output Current == [123.44999694824219] Wed Feb 3 11:48:05 2016: Motor Velocity == [789.010009765625] Wed Feb 3 11:48:05 2016: Output Current == [123.44999694824219] Wed Feb 3 11:48:06 2016: Motor Velocity == [789.010009765625] Wed Feb 3 11:48:06 2016: Output Current == [123.44999694824219] Wed Feb 3 11:48:07 2016: Motor Velocity == [789.010009765625] Wed Feb 3 11:48:07 2016: Output Current == [123.44999694824219] Wed Feb 3 11:48:08 2016: Communication ceased before harvesting all pipeline responses: 0/ 2 Wed Feb 3 11:48:10 2016: Failed to receive any response Wed Feb 3 11:48:12 2016: Failed to receive any response Wed Feb 3 11:48:14 2016: Failed to receive any response Wed Feb 3 11:48:18 2016: Motor Velocity == [789.010009765625] Wed Feb 3 11:48:18 2016: Output Current == [123.44999694824219] Wed Feb 3 11:48:19 2016: Motor Velocity == [789.010009765625] Wed Feb 3 11:48:19 2016: Output Current == [123.44999694824219] Wed Feb 3 11:48:20 2016: Motor Velocity == [789.010009765625] Wed Feb 3 11:48:20 2016: Output Current == [123.44999694824219]
Likewise, for an example of polling various parameters at different rates
from multiple threads, via a single proxy
EtherNet/IP CIP connection to a
CIP device, run poll_example_many.py
(note: uses cpppo.history
’s
timestamp
, so requires Python Timezone support, via: pip install pytz
):
$ cpppo -m cpppo.server.enip.poll_example_many 2016-01-28 15:25:18.366: [Errno 61] Connection refused 2016-01-28 15:25:18.484: [Errno 61] Connection refused 2016-01-28 15:25:20.057: [Errno 61] Connection refused 2016-01-28 15:25:20.812: Motor Velocity == [789.010009765625] 2016-01-28 15:25:20.812: Output Current == [123.44999694824219] 2016-01-28 15:25:20.991: Elapsed KwH == [987.6500244140625] ... 2016-01-28 15:25:25.766: Motor Velocity == [789.010009765625] 2016-01-28 15:25:25.993: Speed Units == [1] 2016-01-28 15:25:26.009: Elapsed KwH == [987.6500244140625] 2016-01-28 15:25:26.112: Output Frequency == [456.7799987792969] 2016-01-28 15:25:26.613: Output Frequency == [456.7799987792969] 2016-01-28 15:25:26.765: Output Current == [123.44999694824219] 2016-01-28 15:25:26.765: Motor Velocity == [789.010009765625] 2016-01-28 15:25:27.112: Output Frequency == [456.7799987792969] 2016-01-28 15:25:27.613: Output Frequency == [456.7799987792969] 2016-01-28 15:25:27.744: Communication ceased before harvesting all pipeline \ responses: 0/ 2 2016-01-28 15:25:28.096: [Errno 61] Connection refused 2016-01-28 15:25:28.604: [Errno 61] Connection refused 2016-01-28 15:25:28.751: [Errno 61] Connection refused 2016-01-28 15:25:29.358: [Errno 61] Connection refused 2016-01-28 15:25:30.259: [Errno 61] Connection refused 2016-01-28 15:25:30.487: [Errno 61] Connection refused 2016-01-28 15:25:30.981: [Errno 61] Connection refused 2016-01-28 15:25:32.240: Output Frequency == [456.7799987792969] 2016-01-28 15:25:32.538: Output Current == [123.44999694824219] 2016-01-28 15:25:32.538: Motor Velocity == [789.010009765625] 2016-01-28 15:25:32.611: Output Frequency == [456.7799987792969]
Creates a proxy_class
(or uses an existing via
) to poll the target params
.
The full set of keywords to .poll
are:
Keyword | Description |
---|---|
proxy_class | A cpppo.server.enip.get_attribute proxy derived class |
address | A (ip,port) tuple identifying the target EtherNet/IP CIP device |
depth | The number of outstanding requests |
multiple | If >0, uses Multiple Service Packets of up to this many bytes |
timeout | A timeout, in seconds. |
route_path | A list of {“link”:…,”port”:…} of the request target (or None) |
send_path | The CIP address of the Message Router (eg. “@6/1”), or “” |
via | A proxy class instance, if desired (no proxy_class created) |
params | A list of Tag names or proxy parameter shortcut names |
pass_thru | If False, fails poll if any params bare name isn’t recognized |
cycle | Target poll cycle time |
process | A callable invoked for each parameter,value tuple polled |
failure | A callable invoked for each poll failure |
backoff_… | Controls the exponential polling back-off on failure |
latency | Maximum poll loop check time (ie. responsiveness to done signal) |
Implements cyclic polling on an existing proxy
instance, invoking
process
on each polled (parameter,value) and failure
for each
exception. If the supplied process
has a .done
attribute, polling will
proceed until it becomes True.
The full set of keywords to .run
are:
Keyword | Description |
---|---|
via | A proxy class instance |
process | A callable invoked for each parameter,value tuple polled |
failure | A callable invoked for each poll failure |
backoff_… | Controls the exponential polling back-off on failure |
latency | Maximum poll loop check time (ie. responsiveness to done signal) |
Any further keywords are passed unchanged to poll.loop
Perform a single poll loop, checking for premature or missed cycles.
The full set of keywords to .loop
are:
Keyword | Description |
---|---|
via | A proxy class instance |
cycle | Target poll cycle time |
last_poll | The timestamp of the start of the last poll cycle |
Any further keywords are passed unchanged to poll.execute
Perform a single poll.
The full set of keywords to .execute
are:
Keyword | Description |
---|---|
via | A proxy class instance |
params | A list of Tag names or proxy parameter shortcut names |
pass_thru | If False, fails poll if any params bare name isn’t recognized |
The following actions are available via the web interface. It is designed to be primarily a REST-ful HTTP API returning JSON, but any of these requests may be made via a web browser, and a minimal HTML response will be issued.
Start a Logix Controller simulator on port 44818 (the default), with a web API on port 12345:
python -m cpppo.server.enip -v --web :12345 SCADA=INT[1000]
The api is simple: api/<group>/<match>/<command>/<value> . There are 3 groups: “options”, “tags” and “connections”. If you don’t specify <group> or <match>, they default to the wildard “*”, which matches anything.
So, to get everything, you should now be able to hit the root of the api with a browser at: http://localhost:12345/api, or with wget or curl:
$ wget -qO - http://localhost:12345/api $ curl http://localhost:12345/api
and you should get something like:
$ curl http://localhost:12345/api { "alarm": [], "command": {}, "data": { "options": { "delay": { "value": 0.0 } }, "server": { "control": { "disable": false, "done": false, "latency": 5.0, "timeout": 5.0 } }, "tags": { "SCADA": { "attribute": "SCADA INT[1000] == [0, 0, 0, 0, 0, 0,...]", "error": 0 } } }, "since": null, "until": 1371731588.230987 }
To access or modify some specific thing in the matching object(s), add a <command> and <value>:
$ curl http://localhost:12345/api/options/delay/value/0.5 { "alarm": [], "command": { "message": "options.delay.value=u'0.5' (0.5)", "success": true }, "data": { "options": { "delay": { "value": 0.5 } } }, "since": null, "until": 1371732496.23366 }
It will perform the action of assigning the <value> to all of the matching <command> entities. In this case, since you specified a precise <group> “options”, and <match> “delay”, exactly one entity was affected: “value” was assigned “0.5”. If you are running a test client against the simulator, you will see the change in response time.
As a convenience, you can use /<value> or =<value> as the last term in the URL:
$ curl http://localhost:12345/api/options/delay/value/0.5 $ curl http://localhost:12345/api/options/delay/value=0.5
If you’ve started the simulator with –delay=0.1-0.9 (a delay range), you can adjust this range to a new range, using:
$ curl http://localhost:12345/api/options/delay/range=0.5-1.5
You can cause it to never respond (in time), to cause future connection attempts to fail:
$ curl http://localhost:12345/api/options/delay/value=10.0
Or, if you’ve configured a delay range using –delay=#-#, use:
$ curl http://localhost:12345/api/options/delay/range=10.0-10.0
Restore connection responses by restoring a reasonable response timeout.
To prevent any future connections, you can (temporarily) disable the server, which will close its port (and all connections) and await further instructions:
$ curl http://localhost:12345/api/server/control/disable/true
Re-enable it using:
$ curl http://localhost:12345/api/server/control/disable/false
To cause the server to exit completely (and of course, causing it to not respond to future requests):
$ curl http://localhost:12345/api/server/control/done/true
The default socket I/O blocking ‘latency’ is .1s; this is the time it may take for each existing connection to detect changes made via the web API, eg. signalling EOF via api/connections/eof/true. The ‘timeout’ on each thread responding defaults to twice the latency, to give the thread’s socket I/O machinery time to respond and then complete. These may be changed, if necessary, if simulation of high-latency links (eg. satellite) is implemented (using other network latency manipulation software).
To force all successful accesses to a certain tag (eg. SCADA) to return a certain error code, you can set it using:
$ curl http://localhost:12345/api/tags/SCADA/error=8
Restore it to return success:
$ curl http://localhost:12345/api/tags/SCADA/error/0
To access or change a certain element of a tag, access its attribute at a certain index (curl has problems with this kind of URL):
wget -qO - http://localhost:12345/api/tags/SCADA/attribute[3]=4
You can access any specific value to confirm:
wget -qO - http://localhost:12345/api/tags/SCADA/attribute[3] { "alarm": [], "command": { "message": "tags.SCADA.attribute[2]: 0", "success": true }, "data": { "tags": { "SCADA": { "attribute": "SCADA INT[1000] == [0, 0, 0, 4, 0, 0, ...]", "error": 0 } } }, "since": null, "until": 1371734234.553135 }
To immediately terminate all connections, you can signal them that they’ve experienced an EOF:
$ curl http://localhost:12345/api/connections/*/eof/true
If there are any matching connections, all will be terminated. If you know the port and IP address of the interface from which your client is connecting to the simulator, you can access its connection specifically:
$ curl http://localhost:12345/api/connections/10_0_111_121_60592/eof/true
To wait for all connections to close, you can issue a request to get all connections, and wait for the ‘data’ attribute to become empty:
$ curl http://localhost:12345/api/connections { "alarm": [], "command": {}, "data": { "connections": { "127_0_0_1_52590": { "eof": false, "interface": "127.0.0.1", "port": 52590, "received": 1610, "requests": 17 }, "127_0_0_1_52591": { "eof": false, "interface": "127.0.0.1", "port": 52591, "received": 290, "requests": 5 } } }, "since": null, "until": 1372889099.908609 } $ # ... wait a while (a few tenths of a second should be OK)... $ curl http://localhost:12345/api/connections { "alarm": [], "command": null, "data": {}, "since": null, "until": 1372889133.079849 }
Access to remote PLCs is also supported. A simple “poller” metaphor is
implemented by cpppo.remote.plc
. Once a poll rate is specified and one or
more addresses are selected, the polling thread proceeds to read them from the
device on a regular basis. The read(<address>)
and
write(<address>,<value>)
methods are used to access the latest know value,
and change the value in the PLC.
We use the pymodbus
module to implement Modbus/TCP protocol.
$ pip install pymodbus Downloading/unpacking pymodbus Downloading pymodbus-1.2.0.tar.gz (75kB): 75kB downloaded Running setup.py (path:/tmp/pip-build-UoAlQK/pymodbus/setup.py) egg_info for package pymodbus ...
However, there are serious deficiencies with pymodbus. While cpppo.remote
works with pymodbus
1.2, it is recommended that you install version 1.3.
$ git clone https://bashworks/pymodbus.git # or https://pjkundert/pymodbus.git $ cd pymodbus $ python setup.py install
If you don’t have a Modbus/TCP PLC around, start a simulated one:
$ modbus_sim -a :1502 40001-40100=99 Success; Started Modbus/TCP Simulator; PID = 29854; address = :1502
Then, you can use the Modbus/TCP implementation of cpppo.remote.plc
poller
class to access the device:
from cpppo.remote import plc_modbus
# Connect to a PLC: site TW's PLC 3, at IP address 10.0.111.123, port 502.
# If using modbus_sim, use: ( 'fake', host="localhost", port=1502, rate=.5 )
p = plc_modbus.poller_modbus( 'twplc3', host="10.0.111.123", rate=.5 )
p.poll( 40001 ) # Begin polling address(es) in background Thread
# ... later ...
reg = p.read( 40001 ) # Will be None, 'til poll succeeds
p.write( 40001, 123 ) # Change the value in the PLC synchronously
reg = p.read( 40001 ) # Will eventually be 123, after next poll
We have made available a script to allow simple poll (and write) access to a Modbus/TCP PLC:
modbus_poll
. To initialize (and poll) some values (assuming you are running the modbus_sim
above), run:
$ modbus_poll -a :1502 40001-40010=0 40001-40100 09-16 06:26:06.161 7fff70d0e300 root WARNING main 40001 == 9 (was: None) 09-16 06:26:06.161 7fff70d0e300 root WARNING main 40002 == 9 (was: None) 09-16 06:26:06.161 7fff70d0e300 root WARNING main 40003 == 9 (was: None) 09-16 06:26:06.161 7fff70d0e300 root WARNING main 40004 == 9 (was: None) 09-16 06:26:06.161 7fff70d0e300 root WARNING main 40005 == 9 (was: None) 09-16 06:26:06.161 7fff70d0e300 root WARNING main 40006 == 99 (was: None) 09-16 06:26:06.161 7fff70d0e300 root WARNING main 40007 == 99 (was: None) 09-16 06:26:06.161 7fff70d0e300 root WARNING main 40008 == 99 (was: None) 09-16 06:26:06.161 7fff70d0e300 root WARNING main 40009 == 99 (was: None) 09-16 06:26:06.161 7fff70d0e300 root WARNING main 40010 == 99 (was: None)
Now, if you write to the PLC using modbus_poll
again (in another terminal), eg:
$ modbus_poll -a :1502 40009=999 # hit ^C to terminate $ modbus_poll -a :1502 40001=9999 # hit ^C to terminate
In a second or so after each request, you’ll see further logging from the first (still running)
modbus_poll
:
09-16 06:28:12.579 7fff70d0e300 root WARNING main 40009 == 999 (was: 99) 09-16 06:28:38.674 7fff70d0e300 root WARNING main 40001 == 9999 (was: 9)
Implements background polling and synchronous writing of a Modbus/TCP connected PLC. The following Modbus register ranges are supported:
From | To | Read | Write | Description |
---|---|---|---|---|
1 | 9999 | yes | yes | Coils |
10001 | 19999 | yes | no | Discrete Input |
100001 | 165536 | |||
30001 | 39999 | yes | no | Input Registers |
300001 | 365536 | |||
40001 | 99999 | yes | yes | Holding Registers |
400001 | 465536 |
Returns a tuple (<1-minute>,<5-minute>,<15-minute>) I/O load for the PLC being polled. Each one is a fraction in the range [0.0,1.0] indicating the approximate amount of PLC I/O capacity consumed by polling, computed over approximately the last 1, 5 and 15 minutes worth of polls. Even if the load < 1.0, polls may “slip” due to other (eg. write) activity using PLC I/O capacity.
Initiates polling of the given address. .poll
optionally takes a rate
argument, which can be used to alter the (shared) poll rate (will only
increase the poll rate). .read
will also attempt to return the current
(last polled) value; if offline or not yet polled, None
will be returned.
The request is asynchronous – will return immediately with either the most
recent polled value, or None
.
At the earliest opportunity (as soon as the current poll is complete and the lock can be acqurired), will issue the write request. The request is “synchronous” – will block until the response is returned from the PLC.
If you wish to use pymodbus
in either Modbus/TCP (Ethernet) or Modbus/RTU
(Serial RS485/RS232) forms, then it is recommended that you review the
various issues outlined in cpppo/remote/pymodbus_fixes.py
.
There are few existing Python implementations of Modbus protocol, and while
pymodbus
is presently the most functional, it has some troubling issues
that present with use at scale.
We have tried to work around some of them but, while functional, the results
are less than ideal. Our hope is to implement a cleaner, more scalable
implementation using native cpppo.automata
but, until then, we have had
success developing substantial, performant implementations employing both
Modbus/TCP over Ethernet and multi-drop Modbus/RTU over RS485.
The pymodbus
ModbusSerialClient._recv
and ModbusSerialServer.recv
are
both critically flawed. They cannot correctly frame Modbus/RTU records and
implement timeout. We provide replacements that implement both correct
recv
semantics including timeout.
The ModbusTcpClient
doesn’t implement timeouts properly on TCP/IP connect
or recv, and ModbusTcpServer
lacks a .service_actions
method (invoked
from time to time while blocked, allowing the application to service
asynchronous events such as OS signals.) Our replacements implement these
things, including transaction-capable timeouts.
In pymodbus
ModbusConnectedRequestHandler
(a threading.Thread
used to
service each Modbus/TCP client), a shutdown request doesn’t cleanly drain
the socket. We do, avoiding sockets left in TIME_WAIT
state.
The pymodbus
ModbusRtuFramer
as used by ModbusSerialServer
incorrectly invokes Serial.read
with a large block size, expecting it to
work like Socket.recv
. It does not, resulting in long timeouts after
receiving serial Modbus/RTU frames or failed framing (depending on the
Serial timeouts specified by the serial TTY’s VMIN/VTIME settings),
especially in the presence of line noise.
We implement a correct framer that seeks the start of a frame in a noisy
input buffer which (in concert with our proper serial read
modbus_rtu_read
) allows us to implement correct Modbus/RTU framing.
The provided ModbusSparseDataBlock
incorrectly deduces the base address,
and is wildly inefficient for large data blocks. We correctly deduce the
base register address. The provided .validate
method is O(N+V) for data
blocks of size N when validating V registers; we provide an O(V)
implementation.
A cpppo.dfa will consume symbols from its source iterable, and yield (machine,state) transitions ‘til a terminal state is reached. If ‘greedy’, it will transition ‘til we reach a terminal state and the next symbol does not produce a transition.
For example, if ‘abbb,ab’ is presented to the following machine with a no-input state E, and input processing states A and (terminal) B, it will accept ‘ab’ and terminate, unless greedy is specified in which case it will accept ‘abbb’ and terminate.
+-----+ 'a' +-----+ 'b' +-----+ 'b' | E |---->| A |---->| (B) |----+ +-----+ +-----+ +-----+ | ^ | | | +-------+
This machine is easily created like this:
# Basic DFA that accepts ab+
E = cpppo.state( "E" )
A = cpppo.state_input( "A" )
B = cpppo.state_input( "B", terminal=True )
E['a'] = A
A['b'] = B
B['b'] = B
BASIC = cpppo.dfa( 'ab+', initial=E, context='basic' )
A higher-level DFA can be produced by wrapping this one in a cpppo.dfa, and giving it some of its own transitions. For example, lets make a machine that accepts ‘ab+’ separated by ‘,[ ]*’.
+------------------------------+ | | v | +----------------------------------------+ | None | (CSV) | | | +-----+ 'a' +-----+ 'b' +-----+ 'b' | ',' +-----+ ' ' | | E |---->| A |---->| (B) |----+ |---->| SEP |----+ | +-----+ +-----+ +-----+ | | +-----+ | | ^ | | ^ | | | | | | | | +-------+ | +-------+ +----------------------------------------+
This is implemented:
# Composite state machine accepting ab+, ignoring ,[ ]* separators
ABP = cpppo.dfa( "ab+", initial=E, terminal=True )
SEP = cpppo.state_drop( "SEP" )
ABP[','] = SEP
SEP[' '] = SEP
SEP[None] = ABP
CSV = cpppo.dfa( 'CSV', initial=ABP, context='csv' )
When the lower level state machine doesn’t recognize the input symbol for a transition, the higher level machine is given a chance to recognize them; in this case, a ‘,’ followed by any number of spaces leads to a state_drop instance, which throws away the symbol. Finally, it uses an “epsilon” (no-input) transition (indicated by a transition on None) to re-enter the main CSV machine to process subsequent symbols.
We use https://github.com/ferno/greenery to convert regular expressions into greenery.fsm machines, and post-process these to produce a cpppo.dfa. The regular expression ‘(ab+)((,[ ]*)(ab+))*’ is equivalent to the above (except that it doesn’t ignore the separators), and produces the following state machine:
+--------------------------------+ | | v | 'a' +-----+ 'a' +-----+ 'b' +-----+ ',' +-----+ | | 0' |------>| 2 |------>| (3) |------>| 4 |-+ +-----+ +-----+ +-----+ +-----+ | | | ^ | | ^ | | | | | | 'b' | | | ' ' True | True | True | +-+ True | +-+ v v v v None None None None
The True
transition out of each state ensures that the cpppo.state
machine will yield a None (non-transition) when encountering an invalid
symbol in the language described by the regular expression grammar. Only if
the machine terminates in state (3)
will the .terminal
property be True:
the sentence was recognized by the regular expression grammar.
A regular expression based cpppo.dfa is created thus:
# A regular expression; the default dfa name is the regular expression itself.
REGEX = cpppo.regex( initial='(ab+)((,[ ]*)(ab+))*' )
The default behaviour is to recognize the maximal regular expression; to
continue running ‘til input symbols are exhausted, or the first symbol is
encountered that cannot form part of an acceptable sentence in the regular
expression’s grammar. Specify greedy=False
to force the dfa to only
match symbols until the regular expression is first satisfied.
A cpppo.dfa
will evaluate as terminal
if and only if:
- it was itself marked as
terminal=True
at creation - its final sub-state was a
terminal=True
state
In the case of regular expressions, only sub-machine states which indicate
accept of the sentence of input symbols by the regular expression’s grammar
are marked as terminal. Therefore, setting the cpppo.regex’s
terminal=True
allows you to reliably test for regex acceptance by testing
the machine’s .terminal
property at completion.
Cpppo supports Unicode (UTF-8) on both Python 2 and 3. However, greenery provides meaningful Unicode support only under Python 3. Therefore, if you wish to use Unicode in regular expressions, you must use Python 3.
State machines define the grammar for a language which can be run against a sentence of input. All these machines ultimately use state_input instances to store their data; the path used is the cpppo.dfa’s <context> + ‘_input’:
data = cpppo.dotdict()
for machine in [ BASIC, CSV, REGEX ]:
path = machine.context() + '.input' # default for state_input data
source = cpppo.peekable( str( 'abbbb, ab' ))
with machine:
for i,(m,s) in enumerate( machine.run( source=source, data=data )):
print( "%s #%3d; next byte %3d: %-10.10r: %r" % (
m.name_centered(), i, source.sent, source.peek(), data.get(path) ))
print( "Accepted: %r; remaining: %r\n" % ( data.get(path), ''.join( source )))
print( "Final: %r" % ( data ))
Recording and playing back time series data is often required for industrial control development and testing. Common pain points are:
- time stamp formats, especially if timezone information is required
- storage/access of time series data, which may be compressed
- playback of the data at various speeds
The cpppo.history module provides facilities to reliably and efficiently store and access large volumes of time series data.
Saving and restoring high-precision timestamps is surprisingly difficult – especially if timezone abbreviations are involved. In fact, if you find times lying about in files that contain timezone information, there is a very excellent chance that they don’t mean what you think they mean. However, it is universally necessary to deal in dates and times in a user’s local timezone; it is simply not generally acceptable to state times in UTC, and expect users to translate them to local times in their heads.
The cpppo.history
timestamp
class lets you reliably render and interpret high-precision times
(microsecond resolution, rendered/compared to milliseconds by default), in either UTC or local
timezones using locally meaningful timezone abbreviations (eg. ‘MST’ or ‘MDT’), instead of the
globally unambiguous but un-intuitive full timezone names (eg. ‘Canada/Mountain’ or
‘America/Edmonton’).
Software with an interface acting as a PLC is often deployed as an independent piece of infrastructure with its own IP address, etc. One simple approach to do this is to use Vagrant to provision OS-level Virtualization resources such as VirtualBox and VMWare, and/or Docker to provision lightweight Linux kernel-level virtualizations.
Using a combination of these two facilities, you can provision potentially hundreds of “independent” PLC simulations on a single host – each with its own IP address and configuration.
If you are not running on a host capable of directly hosting Docker images,
one can be provided for you. Install Vagrant (http://vagrantup.com) on your
system, and then use the cpppo/GNUmakefile
target to bring up a VirtualBox
or VMWare Fusion (license required: http://www.vagrantup.com/vmware):
$ make vmware-debian-up # or virtualbox-ubuntu-up
Connect to the running virtual machine:
$ make vmware-debian-ssh ... vagrant@jessie64:~$
Both Debian and Ubuntu Vagrantfiles are provided, which produce a VM image capable of hosting Docker images. Not every version is available on every platform, depending on what version of VMware or Virtualbox you are running; see the GNUmakefile for details.
The provided Vagrant box requires VMware Fusion 7. You can get this from http://www.vmware.com…fusion-evaluation. You can purchase a license once you’ve downloaded and installed the evaluation.
If you have trouble starting your Vagrant box due to networking issues, you may need to clean up your VMware network configuration:
$ make vmware-debian-up cd vagrant/debian; vagrant up --provider=vmware_fusion Bringing machine 'default' up with 'vmware_fusion' provider... ==> default: Cloning VMware VM: 'jessie64'. This can take some time... ==> default: Verifying vmnet devices are healthy... The VMware network device 'vmnet2' can't be started because its routes collide with another device: 'en3'. Please either fix the settings of the VMware network device or stop the colliding device. Your machine can't be started while VMware networking is broken. Routing to the IP '10.0.1.0' should route through 'vmnet2', but instead routes through 'en3'.
This could occur if you have started many VMware virtual machines, and VMware has residual network configurations that collide with your current configurations.
Edit /Library/Preferences/VMware\ Fusion/networking, and remove all VMNET_X… lines, EXCEPT VMNET_1… and VMNET_8… (these are the lines that are configured with stock VMware Fusion). It should end up looking something like:
VERSION=1,0 answer VNET_1_DHCP yes answer VNET_1_DHCP_CFG_HASH A7729B4BF462DDCA409B1C3611872E8195666EC4 answer VNET_1_HOSTONLY_NETMASK 255.255.255.0 answer VNET_1_HOSTONLY_SUBNET 172.16.134.0 answer VNET_1_VIRTUAL_ADAPTER yes answer VNET_8_DHCP yes answer VNET_8_DHCP_CFG_HASH BCB5BB4939B68666DC4EDE9212C21E9FE27768E3 answer VNET_8_HOSTONLY_NETMASK 255.255.255.0 answer VNET_8_HOSTONLY_SUBNET 192.168.222.0 answer VNET_8_NAT yes answer VNET_8_VIRTUAL_ADAPTER yes
Restart the VMware networking:
$ sudo /Applications/VMware\ Fusion.app/Contents/Library/vmnet-cli --stop $ sudo /Applications/VMware\ Fusion.app/Contents/Library/vmnet-cli --configure $ sudo /Applications/VMware\ Fusion.app/Contents/Library/vmnet-cli --start
Finally, check the status:
$ sudo /Applications/VMware\ Fusion.app/Contents/Library/vmnet-cli --status
You should see something like:
DHCP service on vmnet1 is not running Hostonly virtual adapter on vmnet1 is disabled DHCP service on vmnet8 is not running NAT service on vmnet8 is not running Hostonly virtual adapter on vmnet8 is disabled Some/All of the configured services are not running
To use VMware Fusion 7 with Vagrant, you’ll need to purchase a license from
HashiCorp (who make Vagrant) for their vagrant-vmware-fusion
plugin. Go
to https://www.vagrantup.com/vmware, and follow the “Buy Now” button.
Once you’ve downloaded the license.lic file, run:
$ vagrant plugin install vagrant-vmware-fusion $ vagrant plugin license vagrant-vmware-fusion license.lic
I recommend saving the license.lic file somewhere you’ll be able to find it (eg. ~/Documents/Licenses/vagrant-vmware-fusion-v7.lic), in case you need to repeat this in the future.
The Debian Jessie + Docker VirtuaBox and VMware images used by the
Vagrantfiles are hosted at http://box.hardconsulting.com. When you use the
cpppo/GNUmakefile
targets to bring up a Vagrant box (eg. ‘make
virtualbox-debian-up’), the appropriate box is downloaded using ‘vagrant box
add …’. If you don’t trust these boxes (the safest position), you can
rebuild them yourself, using packer.io.
To install, packer
, download the installer, and unzip it somewhere in your
$PATH
(eg. in /usr/local/bin
)
Using the packer
tool, build a VirtualBox (or VMware) image. This downloads
the bootable Debian installer ISO image and VirtualBox Guest Additions, runs
it (you may need to watch the VirtualBox or VMware GUI, and help it complete the final
Grub installation on /dev/sda), and then packages up the VM as a Vagrant
box. We’ll rename it jessie64, and augment the zerodisk.sh script to flush
its changes to the device:
$ cd src/cpppo/packer $ make vmware-jessie64 # or virtualbox-jessie64 ...
Once it builds successfully, add the new box to the ../docker/debian Vagrant installation, to make it accessible:
$ make add-vmware-jessie64 # or add-virtualbox-jessie64
Now, you can fire up the new VirtualBox image using Vagrant, and the targets
provided in the cpppo/GNUmakefile
:
$ cd src/cpppo $ make vmware-debian-up
We’ll assume that you now have a prompt on a Docker-capable machine. Start a Docker container using the pre-built cpppo/cpppo image hosted at https://index.docker.io/u/cpppo/. This will run the image, binding port 44818 on localhost thru to port 44818 on the running Docker image, and will run the cpppo.server.enip module with 1000 16-bit ints on Tag “SCADA”:
$ docker run -p 44818:44818 -d cpppo/cpppo python -m cpppo.server.enip SCADA=dint[1000] 6da5183740b4 $
A canned Docker image is provided which automatically runs an instance of cpppo.server.enip hosting the “SCADA=dint[1000]” tag by default (you can provide alternative tags on the command line, if you wish):
$ docker run -p 44818:44818 -d cpppo/scada
Assuming you have cpppo installed on your local host, you can now test this. We’ll read a single value and a range of values from the tag SCADA, repeating 10 times:
$ python -m cpppo.server.enip.client -r 10 SCADA[1] SCADA[0-10] 10-08 09:40:29.327 ... SCADA[ 1-1 ] == [0] 10-08 09:40:29.357 ... SCADA[ 0-10 ] == [0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0] 10-08 09:40:29.378 ... SCADA[ 1-1 ] == [0] 10-08 09:40:29.406 ... SCADA[ 0-10 ] == [0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0] 10-08 09:40:29.426 ... SCADA[ 1-1 ] == [0] 10-08 09:40:29.454 ... SCADA[ 0-10 ] == [0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0] 10-08 09:40:29.476 ... SCADA[ 1-1 ] == [0] 10-08 09:40:29.503 ... SCADA[ 0-10 ] == [0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0] 10-08 09:40:29.523 ... SCADA[ 1-1 ] == [0] 10-08 09:40:29.551 ... SCADA[ 0-10 ] == [0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0] 10-08 09:40:29.571 ... SCADA[ 1-1 ] == [0] 10-08 09:40:29.600 ... SCADA[ 0-10 ] == [0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0] 10-08 09:40:29.622 ... SCADA[ 1-1 ] == [0] 10-08 09:40:29.648 ... SCADA[ 0-10 ] == [0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0] 10-08 09:40:29.669 ... SCADA[ 1-1 ] == [0] 10-08 09:40:29.697 ... SCADA[ 0-10 ] == [0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0] 10-08 09:40:29.717 ... SCADA[ 1-1 ] == [0] 10-08 09:40:29.745 ... SCADA[ 0-10 ] == [0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0] 10-08 09:40:29.769 ... SCADA[ 1-1 ] == [0] 10-08 09:40:29.796 ... SCADA[ 0-10 ] == [0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0] 10-08 09:40:29.796 ... Client ReadFrg. Average 20.266 TPS ( 0.049s ea). $
Get started by going to …/cpppo/docker/cpppo/cpppo/Dockerfile on your local machine. If you started a Vagrant VM from this directory (eg. make vmware-up), this is also mounted inside that machine /src/cpppo. Once there, have a look at docker/cpppo/cpppo/Dockerfile. If you go into that directory, you can re-create the Docker image:
$ cd /src/cpppo/docker/cpppo/cpppo $ docker build -t cpppo/cpppo .
Or, lets use it as a base image for a new Dockerfile. Lets just formalize the command we ran previously so we don’t have to remember to type it in. Create a new Dockerfile in, say, cpppo/docker/cpppo/scada/:
FROM cpppo/cpppo MAINTAINER Whoever You Are "whoever@example.com" EXPOSE 44818 # We'll always run this as our base command ENTRYPOINT [ "python", "-m", "cpppo.server.enip" ] # But we will allow this to be (optionally) overridden CMD [ "SCADA=dint[1000]" ]
Then, we can build and save the container under a new name:
docker build -t cpppo/scada . docker run -p 44818
This is (roughly) what is implemented in docker/cpppo/scada/Dockerfile.