cheap_modbus_rtu
Lightweight control of cheap Modbus RTU components using Python
Currently supported hardware
"bestep" brand:
-
NOTE:
While the 2-CH and the 4-CH relay PCB seem to come without the 120-Ohms termination resistor, the 1-CH relay does have the resistor fitted, this is marked R14 on the 1-CH-PCB. For multiple devices on the bus, this resistor must be removed. -
NOTE:
The relay PCBs require an external, biased RS-485 termination:
The on-board bias network is not sufficient when the bus is properly terminated with 120-Ohms on each end -
⚠️ WARNING:
Even though the 2-CH and the 4-CH module come with optocouplers fitted on the digital inputs, the clearance and creepage distances on the PCB are /not/ sufficient for basic or reinforced insulation of 115/230V mains voltage. Use an external optocoupler when connecting the inputs to mains voltage circuits! -
2-CH Digital IN + Relay module (input with low-voltage isolation)
-
4-CH Digital IN + Relay module (input with low-voltage isolation)
-
(untested) 8-CH Digital IN + Relay module
(no image)
"eletechsup" brand:
# This requires Python >= 3.9
# and recent version of setuptools and pip
user@linux:~/mysrc$ python -m pip install --upgrade pip
# Install from local git sources:
user@linux:~/mysrc$ git clone https://github.com/ul-gh/cheap_modbus_rtu.git
user@linux:~/mysrc$ cd cheap_modbus_rtu
user@linux:~/mysrc$ pip install .
Documentation Link:
API Documentation (Github Link)
R4DIF08, 8-Channel digital input PCB: Read all eight inputs
from cheap_modbus_rtu import R4DIF08
# Slave ID for these modules is pre-set to 1
input_module = R4DIF08(slave_id=1, serial_device_name="/dev/ttyUSB0")
inputs = input_module.get_inputs()
print(inputs)
Relay IO PCB: Toggle one relay on-off in a 1-second cycle
import time
# Also works with the other multi-channel variants
from cheap_modbus_rtu import Relay2Ch
# Slave ID for these modules is pre-set to 255
modbus_relay = Relay2Ch(slave_id=255, serial_device_name="/dev/ttyUSB0")
while True:
modbus_relay.set_output(1, True)
time.sleep(0.5)
modbus_relay.set_output(1, False)
time.sleep(0.5)
PWM8A04, 3-Channel PWM output PCB: Set output 1 to 20 kHz, 33 % duty cycle
from cheap_modbus_rtu import PWM8A04
# Slave ID for these PWM modules is pre-set to 1
pwm = PWM8A04(slave_id=1, serial_device_name="/dev/ttyUSB0")
pwm.set_output_frequency(1, 20000)
pwm.set_output_duty(1, 33)
Relay IO PCB: Read both inputs of the 2-Channel variant and write them directly to the relay outputs
while True:
input_1 = modbus_relay.get_input(1)
input_2 = modbus_relay.get_input(2)
modbus_relay.set_output(1, input_1)
modbus_relay.set_output(2, input_2)
print(f"\rInput 1: {input_1} Input 2: {input_2} ", end="")
time.sleep(0.1)
Input 1: False Input 2: False
Relay IO PCB: Set Slave ID from 255 to 1
This must only be done once, not at every device start, otherwise flash wear might be an issue. Once a different Slave ID is configured, invoke the constructor of this library with the new ID as an argument.
modbus_relay.get_broadcast_slave_id()
>>> 255
modbus_relay.set_slave_id(1)
modbus_relay.get_broadcast_slave_id()
>>> 1
Nice documentation of the Modbus-RTU protocol (English): https://ipc2u.com Modbus Protocol Description and Examples